From Bottom Of Machine
- Check the water tank and drip tray to make sure that are no cracks or breaks where water can escape. Make sure they are properly positioned on the machine.
- Ensure that the return line is sitting inside the water tank. If the tube is outside of the tank, or pushed up into the machine it will cause a leak. Position it so that it is sitting inside the water tank.
- Make sure the decompression duct is installed. The decompression duct is a metal tube located to the left of the grouphead. If this tube is missing, water relieved after brewing will not be properly directed into the drip tray.