Troubleshooting-Gaggia-Super-E05-Accademia

From Whole Latte Love Support Library

Poor Or No Flow Or E05 Error

If you are not able to get water to flow through the machine at all, or if the machine displays an E05 code, then something is blocking water flow through the machine. This issue typically indicates the machine is not being cleaned on a regular basis. Review the cleaning & maintenance rundown for this machine, and make sure maintenance is done at least as often as is suggested with the recommended product. Once flow is restored, even if it is minimal flow, a descaling should be done immediately.

  1. The water tank is not seating properly. Please remove the tank and reinsert it firmly. Make sure there are no beans or debris beneath the water tank preventing it from seating flush with the machine.
  2. If you are using an Intenza water filter in the machine then it might be blocking the flow of water. Try removing the water filter and using the machine without it. If the machine works without the water filter, then the filter was blocking the flow of water. Keep the filter out of the machine for the remaining steps.
  3. Debris has been drawn into the system from the water tank. This kind of debris can get lodged in valves/water circuits and cause flow issues.
    • Try cleaning the brew unit check valve using the instructions here:
      Brew Unit Check Valve Cleaning.pdf
  4. Your machine features an e-plus dial, which may be clogged with scale or coffee grinds. Restart the machine. When you hear the pump start vibrating start turning the dial back and forth over and over again. The e-plus dial is the knob located right above the coffee dispensing spout that controls how quickly coffee flows out of the spouts.
  5. If you have been able to restore some flow to the brew circuit, a brew unit cleaning cycle should be completed. The process can be found on pp. 49 of the machine manual.
  6. The machine may require a manual prime.