User contributions
For Giordo (talk | block log | uploads | logs)
This user is currently blocked. The latest block log entry is provided below for reference:
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)
- 07:44, 15 March 2016 (diff | hist) . . (+4) . . Gaggia Anima
- 07:24, 15 March 2016 (diff | hist) . . (-36) . . Gaggia Anima
- 07:22, 15 March 2016 (diff | hist) . . (+36) . . Gaggia Anima
- 07:18, 15 March 2016 (diff | hist) . . (+303) . . N Template:Description-Table-Gaggia-Anima (Created page with "{| class="wikitable" style="float:right; margin-left: 0px;" !colspan=1|Gaggia Anima |- |https://s3.amazonaws.com/store-assets-buckets/products/4372/medlarge/Anima_Spouts_Down....") (current)
- 07:15, 15 March 2016 (diff | hist) . . (+1) . . Template:Troubleshooting-Gaggia-Accademia-Empty-Grounds
- 07:08, 15 March 2016 (diff | hist) . . (+2,174) . . N Gaggia Anima (Created page with "The Gaggia Anima is a [https://en.wikipedia.org/wiki/Espresso_machine#Automation super-automatic] espresso machine that features beverage programming. {{Description-Table-Gagg...")
- 07:04, 15 March 2016 (diff | hist) . . (-1) . . m Template:Troubleshooting-Super-No-Power (→No Power)
- 07:04, 15 March 2016 (diff | hist) . . (-8) . . m Template:Troubleshooting-Super-Wand-Leaking (→From The Wand)
- 07:03, 15 March 2016 (diff | hist) . . (+5) . . m Template:Troubleshooting-Gaggia-Accademia-Bottom-Leaking (→From The Bottom)
- 07:01, 15 March 2016 (diff | hist) . . (+6) . . m Template:Troubleshooting-Gaggia-Super-Flow-Meter-Blocked (→Have Flow But Getting No Flow Error)
- 06:56, 15 March 2016 (diff | hist) . . (-1) . . m Template:Troubleshooting-Super-Brew-Blocked (→Reduced Or No Flow During Brewing)
- 06:53, 15 March 2016 (diff | hist) . . (0) . . m Template:Troubleshooting-Super-No-Crema-Bad-Shots
- 06:44, 15 March 2016 (diff | hist) . . (0) . . Template:Troubleshooting-Super-No-Crema-Bad-Shots
- 06:35, 15 March 2016 (diff | hist) . . (-82) . . Gaggia Accademia
- 06:16, 15 March 2016 (diff | hist) . . (+74) . . m Gaggia Accademia
- 05:56, 15 March 2016 (diff | hist) . . (+4,412) . . N Template:Specifications-Gaggia-Accademia (Created page with "{| class="wikitable" !colspan=2|Basic Specs |- |'''Width:''' |11 in. |- |'''Height:''' |15.2 in. |- |'''Depth:''' |16.8 in. |- |'''Weight:''' |43 lbs. |- |'''Watts:''' |1500 |...")
- 13:30, 14 March 2016 (diff | hist) . . (+450) . . N Template:Support-Documents-Gagia-Accademia (Created page with "{| class="wikitable" !colspan=2|Gaggia Accademia |- |'''Electrical Diagram:''' |File:ACCADEMIA_Electrical_Diagram.pdf |- |'''Hydraulic Diagram:''' |File:ACCADEMIA_Hydrau...")
- 13:30, 14 March 2016 (diff | hist) . . (0) . . N File:ACCADEMIA Startup Guide.pdf (current)
- 13:30, 14 March 2016 (diff | hist) . . (0) . . N File:ACCADEMIA Service Manual.pdf (current)
- 13:30, 14 March 2016 (diff | hist) . . (0) . . N File:ACCADEMIA Parts Diagram.pdf
- 13:29, 14 March 2016 (diff | hist) . . (0) . . N File:ACCADEMIA Machine Manual.pdf (current)
- 13:29, 14 March 2016 (diff | hist) . . (0) . . N File:ACCADEMIA Hydraulic Diagram.pdf (current)
- 13:29, 14 March 2016 (diff | hist) . . (0) . . N File:ACCADEMIA Electrical Diagram.pdf
- 13:25, 14 March 2016 (diff | hist) . . (+8) . . Gaggia Accademia
- 13:23, 14 March 2016 (diff | hist) . . (+2,321) . . N Template:Troubleshooting-Gaggia-Accademia-Brew-Unit-Blocked (Created page with "If the machine says brew unit blocked, or gives an E03 or E04 error code then the machine is sensing that the brew unit motor is working too hard to engage the brew unit. The...")
- 12:22, 14 March 2016 (diff | hist) . . (+1,658) . . N Template:Troubleshooting-Gaggia-Accademia-Empty-Grounds (Created page with "If the machine is giving a continuous empty grounds drawer or empty drip tray message then one of the drip tray sensors is malfunctioning. This happens because the spout on th...")
- 11:05, 14 March 2016 (diff | hist) . . (+1,728) . . N Template:Troubleshooting-Gaggia-Super-Grinder-Blocked-NCS (Created page with "All three of these issues share the same root cause. The grinder has become jammed with grounds or coffee residues. These issues are typically a result of incorrect beans bein...")
- 10:54, 14 March 2016 (diff | hist) . . (+109) . . Gaggia Accademia
- 10:40, 14 March 2016 (diff | hist) . . (+18) . . Gaggia Accademia (→Grinder Issues)
- 10:33, 14 March 2016 (diff | hist) . . (+684) . . N Template:Troubleshooting-Gaggia-Accademia-Brew-Cold (Created page with "====Cold Shots or E14 Error==== #If the machine is producing shots that are hot, but you would like them to be hotter check the beverage programming menu. Make sure all of th...")
- 10:30, 14 March 2016 (diff | hist) . . (+337) . . Template:Troubleshooting-Super-Brew-Blocked (→Reduced Or No Flow During Brewing)
- 10:20, 14 March 2016 (diff | hist) . . (+1,346) . . N Template:Troubleshooting-Gaggia-Accademia-Steam-Cold (Created page with "====No Steam Or E15 Error==== #If you are getting no steam, but not getting an E15 Error then there may just be a blockage in the steam circuit. Do the cleanings suggested in...")
- 09:48, 14 March 2016 (diff | hist) . . (+779) . . N Template:Troubleshooting-Gaggia-Accademia-Stuck-In-Standby (Created page with "====Stuck In Standby Mode==== If the machine is powering on but not leaving standby mode, then there may be an issue with the standby button or an electrical issue. The stand...")
- 09:36, 14 March 2016 (diff | hist) . . (+1,922) . . N Template:Troubleshooting-Super-No-Power (Created page with "====No Power==== #Make sure the machine is plugged into an appropriate power source. ##Do not use the machine on a surge protector. This machine has a high power draw, more th...")
- 09:29, 14 March 2016 (diff | hist) . . (+22) . . Gaggia Classic
- 09:29, 14 March 2016 (diff | hist) . . (+2) . . Template:Troubleshooting-Gaggia-Classic-No-Power
- 09:27, 14 March 2016 (diff | hist) . . (-3) . . Gaggia Accademia (→Basic Usage)
- 09:19, 14 March 2016 (diff | hist) . . (+1,459) . . N Template:Troubleshooting-Gaggia-Accademia-Spout-Leaking (Created page with "====From Dispensing Spout==== Dispensing Spout If coffee is leaking around the spout assembly, or from the front of it, then it i...")
- 09:18, 14 March 2016 (diff | hist) . . (0) . . m File:GAGGIA-ACCADEMIA-Spout-Right.JPG (Giordo moved page File:GAGGIA-ACCADEMIA-Spout-right.JPG to File:GAGGIA-ACCADEMIA-Spout-Right.JPG without leaving a redirect) (current)
- 09:08, 14 March 2016 (diff | hist) . . (0) . . N File:GAGGIA-ACCADEMIA-Spout-Removed.jpg (current)
- 09:06, 14 March 2016 (diff | hist) . . (+91) . . Gaggia Accademia
- 09:01, 14 March 2016 (diff | hist) . . (0) . . N File:GAGGIA-ACCADEMIA-Spout.jpg (current)
- 08:56, 14 March 2016 (diff | hist) . . (-13) . . Template:Troubleshooting-Gaggia-Accademia-Bottom-Leaking
- 08:46, 14 March 2016 (diff | hist) . . (+569) . . N Template:Troubleshooting-Super-Wand-Leaking (Created page with "====From The Wand==== If leaking the steam wand is leaking while the machine is on or during brewing then there is a valve that is stuck open in side the machine. Try the fol...")
- 08:38, 14 March 2016 (diff | hist) . . (+2,340) . . N Template:Troubleshooting-Gaggia-Accademia-Bottom-Leaking (Created page with "====From The Bottom==== #Check the internal drip tray. The old style of drip tray uses two rubber plugs at the back which helped reduce vibration during brewing. If one of bo...")
- 08:14, 14 March 2016 (diff | hist) . . (0) . . N File:GAGGIA-ACCADEMIA-Spout-Wrong.jpg (current)
- 08:13, 14 March 2016 (diff | hist) . . (0) . . N File:GAGGIA-ACCADEMIA-Spout-Right.JPG
- 07:48, 14 March 2016 (diff | hist) . . (0) . . N File:ACCADEMIA Missing Drip Tray Grommet.jpg (current)
- 07:12, 14 March 2016 (diff | hist) . . (+1,277) . . N Template:Troubleshooting-Gaggia-Super-Flow-Meter-Blocked (Created page with "====Have Flow But Getting No Flow Error==== In some situations you will be able to get flow through the machine for all of the functions, but the machine thinks there is no w...")
- 06:48, 14 March 2016 (diff | hist) . . (0) . . m Template:Troubleshooting-Super-Brew-Blocked
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)