|
|
(One intermediate revision by one other user not shown) |
Line 1: |
Line 1: |
− | The Expobar Office Control is a [[:Category:Prosumers|Prosumer]] espresso machine designed for home or office use. {{Description-Table
| + | {{Getting-Started |
− | |title = Expobar Office Control | + | |brand = Expobar |
− | |machine_image = [[File:EXPOBAR_OFFICE_CONTROL.jpg|400px|none]] | + | |machine_type = Prosumers |
− | |manufacturer = [[:Category:Expobar|Expobar]] | + | |product_banner = [[File:Wiki_ProductPageBanner_1200x175_ExpobarOfficeControl_v1.jpg]] |
− | |model_name = Control | + | |product_page_title = Expobar Office Control |
− | |type = [[:Category:Prosumers|Prosumer]] | + | |page_type = set up |
− | |buy_button = Yes | + | |section1 = Install It |
− | |button_size = 400px | + | |anchor1 = Install |
− | |button_link = https://www.wholelattelove.com/products/expobar-office-control-espresso-machine | + | |section2 = Get it Good & Hot |
| + | |anchor2 = Heating |
| + | |section3 = Get a Handle on your Tamp |
| + | |anchor3 = Tamping |
| + | |section4 = Brew Better |
| + | |anchor4 = Brew Better |
| + | |section5 = Brew the Best You Can Brew |
| + | |anchor5 = Brew Best |
| + | |section6 = Get Frothing |
| + | |anchor6 = Get Frothing |
| + | |section7 = Froth Better |
| + | |anchor7 = Froth Better |
| + | |section8 = Frothing and Habits to Avoid |
| + | |anchor8 = Frothing Mistakes |
| + | |section9 = Steam & the Heating Sweet Spot |
| + | |anchor9 = Steaming Temperature |
| + | |section10 = Steam with Thermometers |
| + | |anchor10 = Steam with Thermometers |
| }} | | }} |
− | ==Basic Usage==
| + | {{Set-Up-Content |
− | | + | |dual_boiler = |
− | ===Getting Started===
| + | |e61 = no |
− | | + | |
− | {{#ev:youtube|https://www.youtube.com/watch?v=c0HvW3-J0Do|480|center}} | + | |
− | | + | |
− | ===Adjusting Brew Pressure===
| + | |
− | | + | |
− | {{#ev:youtube|https://www.youtube.com/watch?v=torXYzDE2y0|480|center}}
| + | |
− | | + | |
− | ===Draining The Boiler===
| + | |
− | | + | |
− | {{#ev:youtube|https://www.youtube.com/watch?v=ln25nJbyQQc|480|center}}
| + | |
− | | + | |
− | | + | |
− | == Cleaning & Maintenance ==
| + | |
− | | + | |
− | {{Maintenance-Prosumer
| + | |
− | |single_heat_exchange = Yes | + | |
− | |group_gasket_link = The gasket can be purchased [https://www.wholelattelove.com/group-gasket-for-all-expobar-models-8-0mm here]. Instructions for replacing the gasket can be found below:[[File:EXPOBAR BREWTUS & LEVER Gasket Changing.pdf|250px|thumbnail|center|Group Gasket Changing Instructions]] | + | |
− | |descaling_products = The machine can be descaled using [https://www.wholelattelove.com/urnex-full-circle-descaling-liquid Urnex Full Circle Cleaning Liquid].
| + | |
− | |softener_info = This machine has a water softener cartridge available. The water softener should be replaced every 3 months. To make the water softener more effective it should be recharged on a monthly basis. The following document explains how to recharge the water softener: [[File:EXPOBAR ALL Recharging Water Softener.pdf|250px|thumbnail|center|Water Softener Recharging Instructions]] Replacement water softeners can be purchased [https://www.wholelattelove.com/expobar-water-softener-cartridge here].
| + | |
| }} | | }} |
− | | + | [[Category:Expobar]] |
− | {{Maintenance-Draining-HX-Boiler}}
| + | |
− | | + | |
− | == Troubleshooting ==
| + | |
− | | + | |
− | ===No Crema or Bad Tasting Shots===
| + | |
− | | + | |
− | {{Troubleshooting-No-Crema-Bad-Shots}}
| + | |
− | | + | |
− | | + | |
− | ===Difficulty Frothing===
| + | |
− | | + | |
− | {{Troubleshooting-Frothing}}
| + | |
− | | + | |
− | | + | |
− | ===Flow Issues===
| + | |
− | | + | |
− | The first place to start with any flow issue is cleaning the machine. Before going through these steps please make sure the machine is cleaned according to the [[#Cleaning & Maintenance|Cleaning & Maintenance]] section of this article.
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-No-Steam
| + | |
− | |steam_gauge = No
| + | |
− | |vacuum_relief_instr = Instructions for cleaning the vacuum relief valve can be found in the video below: {{#ev:youtube|https://www.youtube.com/watch?v=ecR9nDsORd8|480|center}}
| + | |
− | |hls_reset_instr = Instructions for resetting the high limit switch can be found in this document:[[File:EXPOBAR_CONTROL_&_PULSER_High_Limit_Reset_Instructions.pdf|250px|thumbnail|center|High Limit Switch Reset Instructions]]
| + | |
− | |pstat_picture = [[File:EXPOBAR OFFICE LEVER 2-Wire Pressurestat.gif|200px|super|thumbnail|right|2-Wire Pressurestat]]
| + | |
− | |pstat_adjust_instr = Instructions for adjusting the pressurestat can be found in the document below. Please note that if your machine was bought used or repaired at any point the 2-Wire style of pressurestat may have been replaced with a 3-Wire version. [[File:EXPOBAR_OFFICE_CONTROL_&_PULSER_Pressurestat_Adjustment.pdf|250px|thumbnail|center|2-Wire Pressurestat Adjustment Instructions]]
| + | |
− | |pstat_rep_instr = A replacement pressurestat can be purchased [https://www.wholelattelove.com/2-wire-pressurestat-ceme-wide-band here].
| + | |
− | }}
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-Brew-Blocked
| + | |
− | |programmable_shots = Yes
| + | |
− | |grouphead_instr = Instructions for taking the grouphead apart for cleaning can be found below:[[File:EXPOBAR_OFFICE_CONTROL_&_PULSER_Group_Clean_&_Backflush.pdf|250px|thumbnail|center|Backflushing & Grouphead Cleaning Instructions]]
| + | |
− | |backflush_instr = Backflushing instructions can be found in the tech document from the previous step.
| + | |
− | |valve_instr = Instructions for taking the OPV valve assembly apart for cleaning can be found below: [[File:EXPOBAR OFFICE PULSER OPV Valve Repair.pdf|250px|thumbnail|center|OPV Cleaning Instructions]]
| + | |
− | }}
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-No-Hot-Water
| + | |
− | |steam_gauge = No
| + | |
− | |vacuum_relief_instr = Instructions for cleaning the vacuum relief valve can be found in the video below: {{#ev:youtube|https://www.youtube.com/watch?v=ecR9nDsORd8|480|center}}
| + | |
− | |hls_reset_instr = Instructions for resetting the high limit switch can be found in this document:[[File:EXPOBAR_CONTROL_&_PULSER_High_Limit_Reset_Instructions.pdf|250px|thumbnail|center|High Limit Switch Reset Instructions]]
| + | |
− | |pstat_picture = [[File:EXPOBAR OFFICE LEVER 2-Wire Pressurestat.gif|200px|super|thumbnail|right|2-Wire Pressurestat]]
| + | |
− | |pstat_adjust_instr = Instructions for adjusting the pressurestat can be found in the document below. Please note that if your machine was bought used or repaired at any point the 2-Wire style of pressurestat may have been replaced with a 3-Wire version. [[File:EXPOBAR_OFFICE_CONTROL_&_PULSER_Pressurestat_Adjustment.pdf|250px|thumbnail|center|2-Wire Pressurestat Adjustment Instructions]]
| + | |
− | |pstat_rep_instr = A replacement pressurestat can be purchased [https://www.wholelattelove.com/2-wire-pressurestat-ceme-wide-band here].
| + | |
− | }}
| + | |
− | | + | |
− | ====No Flow At All====
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-No-Flow-At-All
| + | |
− | |water_supply = Reservoir
| + | |
− | |sensor_instr = The water tank sensor may be wired incorrectly. This video below will explain how to rewire the sensor correctly: {{#ev:youtube|https://www.youtube.com/watch?v=UIiLeRdVWAU|480|center|||start=61}}
| + | |
− | |pump_instr = This video will explain how to test for electrical pump issues:{{#ev:youtube|https://www.youtube.com/watch?v=UIiLeRdVWAU|480|center|||start=961}}
| + | |
− | |valve_instr = Check to make sure the fill valve is operational. This video will explain how to see if the fill valve is activating properly:{{#ev:youtube|https://www.youtube.com/watch?v=UIiLeRdVWAU|480|center|||start=1088}}
| + | |
− | }}
| + | |
− | | + | |
− | ===Machine Is Leaking===
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-Bad-Gasket
| + | |
− | |gasket_instr = Instructions for changing the gasket can be found here: [[File:EXPOBAR BREWTUS & LEVER Gasket Changing.pdf|250px|thumbnail|center|Group Gasket Changing Instructions]] A replacement group gasket can be purchased [https://www.wholelattelove.com/group-gasket-for-office-lever-and-brewtus-8-5mm here].
| + | |
− | }}
| + | |
− |
| + | |
− | {{Troubleshooting-Prosumer-Bottom-Leak
| + | |
− | |water_source = Reservoir
| + | |
− | |tube_reservoir = Yes
| + | |
− | |level_probe_instr = The water level probe can be cleaned by removing it from the boiler. First make sure the machine is unplugged and fully cooled off. The probe is listed as part 4 on p.11 of the machine's parts diagram.
| + | |
− | ####The probe is secured to the boiler by a bolt. Use an open ended wrench or adjustable wrench to remove the probe. Newer versions of the machine will have a two bolt assembly. Remove the smaller upper bolt to access the probe.
| + | |
− | ####Once the probe is removed clean it off. Soak the probe in a solution of hot water and backflushing powder.
| + | |
− | ####If the probe has a large amount of scale buildup on it a scrubby sponge can be used to remove the scale buildup. Do not use a metal scrubber as it can damage the probe.
| + | |
− | ####Also examine the wiring of the probe to make sure it is intact and is attached to the power board of the machine.
| + | |
− | }}
| + | |
− |
| + | |
− | {{Troubleshooting-Prosumer-Top-Steaming
| + | |
− | |vacuum_cleaning_instr = {{#ev:youtube|https://www.youtube.com/watch?v=ecR9nDsORd8&ab_channel=WholeLatteLove|480|center}}
| + | |
− | |vacuum_replace_link = A replacement vacuum relief can be purchased [https://www.wholelattelove.com/vacuum-relief-valve-rubber-seal here]
| + | |
− | |steam_adjust_style = Gauge
| + | |
− | |pstat_adjust_instr = Instructions for adjusting the pressurestat can be found in the document below:[[File:EXPOBAR_OFFICE_CONTROL_&_PULSER_Pressurestat_Adjustment.pdf|250px|thumbnail|center|2-Wire Pressurestat Adjustment Instructions]]
| + | |
− | |relief_stuck_instr = The pressure relief valve is attached to the top of a t-junction, which is listed as part 7 on p.11 of the machine's parts diagram. The relief valve is not pictured on the diagram, but a picture of the part is shown below: [[File:EXPOBAR OFFICE CONTROL & PULSER Pressure Relief Valve.jpg|250px|thumbnail|center|Pressure Relief Valve]] Make sure the machine is turned off and cooled down. Then use an open ended wrench or adjustable wrench to unscrew this part from the boiler. Soak the valve in a solution of hot water and backflushing powder, and use a grouphead cleaning brush to remove any major scale deposits on the part.
| + | |
− | }}
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-Wand-Leak
| + | |
− | |knob_instr =<br />
| + | |
− | ##Pop the cover of the knob off. This can typically be done by hand, but a flathead screw driver can be used as well.
| + | |
− | ##Once the cover is removed the knob should look like this. If the knob is spinning in place continuously then the clip is broken. The clip is shown below, with a red arrow pointing to it: [[File:EXPOBAR OFFICE CONTROL & PULSER Knob No Cover.jpg|400px|thumbnail|center|Knob with cover removed.]]
| + | |
− | |descalable = Yes
| + | |
− | |tip_instr = <br />
| + | |
− | ##The steam tip o-ring is easy to access. Simply remove the steam tip and there will be a small o-ring between the tip the wand arm. Inspect this o-ring for damage and clean it.
| + | |
− | ##The hot water tip is a little more complicated, but still easily accessed and cleaned.
| + | |
− | ###First unscrew the entire tip assembly from the wand arm. [[File:EXPOBAR BREWTUS IV Hot Water Tip Removed.jpg|200px|thumbnail|center|Hot Water With Tip Removed]]
| + | |
− | ###There will be an o-ring between the tip assembly and the wand arm. If the leaking was coming from here, then this o-ring needs to be cleaned and repositioned, or if it is damaged it will need to be replaced. [[File:EXPOBAR BREWTUS IV Hot Water O-ring.jpg|200px|thumbnail|center|The red arrow points to the described o-ring]]
| + | |
− | ###If the leaking was coming from farther down on the tip, then the tip will need to be disassembled further to troubleshoot. To disassemble the tip further simply twist the two halves of the tip assembly in opposite directions. [[File:EXPOBAR BREWTUS IV Hot Water Tip Disassembly.jpg|400px|thumbnail|center|Twist in the direction of the arrows shown.]]
| + | |
− | ###Once the tip is apart it will separate into four separate pieces. There will be three metal pieces and another o-ring. Inspect the o-ring for cleanliness and damage. The metal pieces can be soaked in a solution of hot water and backflushing powder to remove and scale buildup on them. [[File:EXPOBAR BREWTUS IV Hot Water Tip Blowout.jpg|400px|thumbnail|center|The disassembled hot water tip.]]
| + | |
− | }}
| + | |
− | | + | |
− | ===Machine Not Heating Or Powering On===
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-No-Power}}
| + | |
− | #The video below also systematically goes through the electronic systems on an Expobar unit. It may help you identify the cause of the issue.
| + | |
− | {{#ev:youtube|https://www.youtube.com/watch?v=UIiLeRdVWAU|480|center}}
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-Brew-Cold
| + | |
− | |temp_adjust_style = Pressurestat
| + | |
− | |pstat_adjust_instr = Instructions for adjusting the pressurestat can be found in the document below. Please note that if your machine was bought used or repaired at any point the 2-Wire style of pressurestat may have been replaced with a 3-Wire version.[[File:Pressure-stat-adj-Pulsar-Control.pdf|250px|thumbnail|center|2-Wire Pressurestat Adjustment Instructions]]
| + | |
− | |hls_instr = Instructions for resetting the high limit switch can be found in this document:[[File:EXPOBAR_CONTROL_&_PULSER_High_Limit_Reset_Instructions.pdf|250px|thumbnail|center|High Limit Switch Reset Instructions]]
| + | |
− | |element_testing_instr = Instructions for testing the heating element can be found in the video below: {{#ev:youtube|https://www.youtube.com/watch?v=UIiLeRdVWAU|480|center|||start=774}}
| + | |
− | #:It is highly suggested that if the machine has a bad heating element that the machine be sent in for repair. Replacement of this element is complex, and can cause damage to the machine if not done properly. We suggest reviewing the instructions below before purchasing an element. If you are not comfortable with any part of the instructions you should not attempt the replacement.[[File:EXPOBAR ALL Replacing The Element.pdf|250px|thumbnail|center|Element Replacement Instructions]]
| + | |
− | }}
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-Steam-Cold
| + | |
− | |steam_test_instr = Instructions for doing a steam test for the machine can be found in the video below: {{#ev:youtube|https://www.youtube.com/watch?v=iM_kVx-Fr3M|480|center}}
| + | |
− | |temp_adjust_style = Pressurestat
| + | |
− | |pstat_adjust_instr = Instructions for adjusting the pressurestat can be found in the document below. Please note that if your machine was bought used or repaired at any point the 2-Wire style of pressurestat may have been replaced with a 3-Wire version. [[File:EXPOBAR OFFICE LEVER 2-Wire Pressurestat Adjustment.pdf|250px|thumbnail|center|2-Wire Pressurestat Adjustment Instructions]]
| + | |
− | |hls_instr = Instructions for resetting the high limit switch can be found in this document:[[File:EXPOBAR_CONTROL_&_PULSER_High_Limit_Reset_Instructions.pdf|250px|thumbnail|center|High Limit Switch Reset Instructions]]
| + | |
− | |element_testing_instr = Instructions for testing the heating element can be found in the video below: {{#ev:youtube|https://www.youtube.com/watch?v=UIiLeRdVWAU|480|center|||start=774}}
| + | |
− | #:It is highly suggested that if the machine has a bad heating element that the machine be sent in for repair. Replacement of this element is complex, and can cause damage to the machine if not done properly. We suggest reviewing the instructions below before purchasing an element. If you are not comfortable with any part of the instructions you should not attempt the replacement.[[File:EXPOBAR ALL Replacing The Element.pdf|250px|thumbnail|center|Element Replacement Instructions]]
| + | |
− | }}
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-No-Heat
| + | |
− | |hls_reset_instr = Instructions for resetting the high limit switch can be found in this document:[[File:EXPOBAR_CONTROL_&_PULSER_High_Limit_Reset_Instructions.pdf|250px|thumbnail|center|High Limit Switch Reset Instructions]]
| + | |
− | }}
| + | |
− | | + | |
− | {{Template:Troubleshooting-Expobar-Replace-Pressurestat}}
| + | |
− | | + | |
− | ===Portafilter Handle Not Fitting On Machine===
| + | |
− | | + | |
− | {{Troubleshooting-Prosumer-Portafilter}}
| + | |
− | | + | |
− | ===Shots Run Too Long/Don't Stop===
| + | |
− | | + | |
− | If you've programmed one of the buttons to a particular amount and the machine is going over the programmed volume, or the machine won't stop flowing when you hit one of the programmed brew options, there are a few things to try:
| + | |
− | #Make sure that you are programming your shots with coffee in the portafilter basket. If the machine is programmed with an empty portafilter basket the shot volume will be altered. The video below shows how to program a shot on the machine. {{#ev:youtube|https://www.youtube.com/watch?v=c0HvW3-J0Do|480|center|||start=221}}
| + | |
− | #If the machine is still producing inconsistent shot amounts try programming a shot without coffee and see if the machine saves the amount properly. Inconsistency in the grind itself could cause varying amounts of backpressure during brewing, resulting in a variance in the total shot volume. If the machine produces a consistent volume without coffee this may indicate that your grinder needs calibration.
| + | |
− | #If the machine flows water continuously when you press a programmed brew button there are two causes:
| + | |
− | ##First, the machine may have accidentally been put into programming mode. If all of the lights are lit up, or both the manual light and the light above the button you pressed are both lit, then the machine is in programming mode. The machine will not stop flowing until you hit the brew button your pressed again.
| + | |
− | ##There may be an issue with the flowmeter. The flowmeter is a device inside the machine that detects how much water has passed through the system when the brew circuit is activated. This is the device responsible for measuring shot length for the programmed shots. This part can become blocked or dirty. The flowmeter is listed as part 9 on p. 9 of the parts diagram. This part should be taken apart for cleaning. The older version of this part simply twists apart for cleaning, while the newer version will require some screws to be removed. A blown up view of the new version can be found on p. 14 of the machine's parts diagram.
| + | |
− | | + | |
− | | + | |
− | ==Diagrams & Manuals==
| + | |
− | | + | |
− | {{Support-Documents
| + | |
− | |title = Expobar Office Control
| + | |
− | |hydraulic_diagram = [[File:OFFICE_CONTROL_Hydraulic_Diagram.pdf|150px]]
| + | |
− | |machine_manual = [[File:OFFICE LEVER Machine Manual.pdf|150px]]
| + | |
− | |parts_diagram = [[File:OFFICE_CONTROL_Parts_Diagram.pdf|150px]]
| + | |
− | }}
| + | |
− |
| + | |
− | ==Specifications==
| + | |
− | | + | |
− | {{Specifications-Prosumer
| + | |
− | |basic_specs = Yes
| + | |
− | |width = 9.5 in.
| + | |
− | |height = 15.25 in.
| + | |
− | |depth = 16.5 in.
| + | |
− | |weight = 36 lbs
| + | |
− | |watts = 1428
| + | |
− | |volts = 120
| + | |
− | | + | |
− | |housing = Yes
| + | |
− | |housing_material = Stainless Steel
| + | |
− | |drip_tray_material = Plastic
| + | |
− | |drip_tray_cover_material = Stainless Steel
| + | |
− | |drip_tray_capacity = 20 oz.
| + | |
− | |power_cord_length = 40 in.
| + | |
− | | + | |
− | |cup_height = Yes
| + | |
− | |max_cup_height = 3.25 in.
| + | |
− | | + | |
− | |frothing = Yes
| + | |
− | |wand_material = Stainless Steel
| + | |
− | |wand_style = Commercial Style
| + | |
− | |wand_movement = Articulating
| + | |
− | |usable_length = 5.75 in.
| + | |
− | |height_off_counter = 6.75 in.
| + | |
− | |number_of_holes = 1
| + | |
− | |optional_tips = Yes
| + | |
− | | + | |
− | |water_source = Yes
| + | |
− | |source_type = Reservoir
| + | |
− | |reservoir_capacity = 93 oz.
| + | |
− | |reservoir_material = Plastic
| + | |
− | |reservoir_removable = Yes
| + | |
− | | + | |
− | |controls = Yes
| + | |
− | |control_type = Push Button
| + | |
− | |programmable_brewing = Yes
| + | |
− | |cup_volume_control = Yes
| + | |
− | |low_water_warning = Yes
| + | |
− | |steam_control = Yes
| + | |
− | | + | |
− | |cup_warmer = Yes
| + | |
− | |warmer_material = Stainless Steel
| + | |
− | |warmer_size = 10 in. x 8 in.
| + | |
− | |warmer_type = Passive
| + | |
− | | + | |
− | |portafilter = Yes
| + | |
− | |portafilter_material = Chrome Plated Brass
| + | |
− | |portafilter_type = Commercial Style
| + | |
− | |quantity_included = 1
| + | |
− | |portafilter_weight = 1 lb
| + | |
− | |portafilter_diameter = 58 mm.
| + | |
− | |commercial_baskets = Single & Double
| + | |
− | |pod_compatibility = Pod Kit Available
| + | |
− | |bottomless_portafilter = Yes
| + | |
− | |tamper_size = 58 mm.
| + | |
− | | + | |
− | |brew_group = Yes
| + | |
− | |group_material = Chrome Plated Brass
| + | |
− | |group_type = E61
| + | |
− | |preheat = Yes
| + | |
− | |solenoid = Electric
| + | |
− | |capsule_friendly = Pod Kit Available
| + | |
− | |back_flushable = Yes
| + | |
− | | + | |
− | |boiler_data = Yes
| + | |
− | |num_boilers = 1
| + | |
− | |brew_steam_simultaneous = Yes
| + | |
− | | + | |
− | |brew_boiler = Yes
| + | |
− | |brew_boiler_type = Heat Exchanger
| + | |
− | |brew_boiler_wattage = 1250
| + | |
− | |brew_boiler_volume = 1.7 Liter
| + | |
− | |brew_boiler_material = Copper
| + | |
− | |brew_boiler_orientation = Vertical
| + | |
− | |brew_element_location = Internal
| + | |
− | |brew_boiler_autofill = Yes
| + | |
− | |brew_boiler_insulated = Yes
| + | |
− | | + | |
− | |steam_boiler = Yes
| + | |
− | |steam_boiler_type = One Boiler For Brew & Steam
| + | |
− | | + | |
− | |pump_data = Yes
| + | |
− | |pump_type = Vibration
| + | |
− | |pump_wattage = 41
| + | |
− | |pump_pressure = 15 Bar
| + | |
− | |pump_pressure_adjust = Yes
| + | |
− | |pump_deairator = Yes
| + | |
− | |pump_self_prime = 8 to 9 bar
| + | |
− | | + | |
− | |performance = Yes
| + | |
− | |heat_up = 420 s.
| + | |
− | |recommended_heat_up = 900 s.
| + | |
− | |steam_time_8 = 63 s.
| + | |
− | |hot_water_temp_8 = 195 F°
| + | |
− | |hot_water_time_8 = 13 s.
| + | |
− | |brew_sound_level = 59 Db
| + | |
− | | + | |
− | |details = Yes
| + | |
− | |manufacture_country = Spain
| + | |
− | |recommended_application = Home/Commercial
| + | |
− | }}
| + | |
− |
| + | |
− | <!-- Categories -->
| + | |
| [[Category:Prosumers]] | | [[Category:Prosumers]] |
− | [[Category:Expobar]]
| |