Line 175: Line 175:
 
| ErrorCode_21 || Boiler steam overheating || Zero crossing error: occurs when the C.A. It does not detect the signal zero crossing.
 
| ErrorCode_21 || Boiler steam overheating || Zero crossing error: occurs when the C.A. It does not detect the signal zero crossing.
 
|}
 
|}
 +
 +
=== Descaling Cycle Frequency ===
 +
{| class="wikitable"
 +
|-
 +
! Hardness !! Water Hardness !! Without Water Filter !! Not Reactivating the Filter
 +
|-
 +
| 1 || Soft water (up to 7°dH) || Approx. every 6 months / 240 litres || 210 litres
 +
|-
 +
| 2 || Medium water (7° - 14°dH) || Approx. every 3 months / 120 litres || 105 litres
 +
|-
 +
| 3 || Hard water (15° - 21°dH) || Approx. every 6 weeks or 60 litres || 52.5 litres
 +
|-
 +
| 4 || Very hard water (over 21°dH) || Approx. every 4 weeks or 30 litres || 26.25 litres
 +
|}
 +
The default water hardness level is 4. Each litre of water corresponds to approximately 2,000 pulses.

Revision as of 10:00, 30 September 2020

Accademia Error Codes

Error Code Brief Description Description
01 blocked coffee grinder the coffee grinder is blocked (jammed grinder blades or sensor is not reading properly)
03 brewing unit blocked in ‘work’ descending time-out exceeded
04 brewing unit blocked in ‘home’ ascending time-out exceeded
05 blocked water circuit water does not flow in the flow meter
06 frother unit solenoid valve short circuit in a solenoid valve of the frother unit
10 coffee boiler short circuit coffee boiler temperature sensor short circuit
11 coffee boiler in open circuit coffee boiler temperature sensor in open circuit
12 steam boiler short circuit steam boiler temperature sensor short circuit
13 steam boiler in open circuit steam boiler temperature sensor in open circuit
14 various temperature errors (in the coffee boiler) coffee boiler temperatures out of control
15 various temperature errors (in the steam boiler) steam boiler temperatures out of control
16 coffee unit short circuit brewing unit microswitch short circuit
18 clock error memory fault or impossible to set
19 no zero crossing no zero crossing on board, could also be caused by the power board

Accademia Descaling Cycle Frequency

Hardness Water Hardness Without Water Filter With Water Filter
1 Soft water (up to 7°dH) "Approx. every 6 months / 240 litres" Approx. every 12 months / 480 litres
2 Medium water (7° - 14°dH) Approx. every 3 months / 120 litres "Approx. every 6 months / 240 litres"
3 Medium water (7° - 14°dH) "Approx. every 6 weeks or 60 litres" "Approx. every 3 months / 120 litres"
4 "Very hard water (over 21°dH)" "Approx. every 4 weeks or 30 litres" "Approx. every 6 weeks or 60 litres"

The default water hardness level is 3. Each litre of water corresponds to approximately 2,000 pulses

Anima Error Key

Symbol Brief Description
Anima error 1.PNG Put back the drip tray and coffee grounds drawer; close the service door.
Anima error 2.PNG Coffee bean hopper empty.
Anima error 3.PNG Brew group not inserted.
Anima error 4.PNG The machine is out of service.
Anima error 5.PNG Coffee grounds drawer full.
Anima error 6.PNG Water tank empty.
Anima error 7.PNG N/A
Anima error 8.PNG The machine is ready to brew products: coffee bean hopper empty
Anima error 9.PNG The machine is ready to brew products: replace the INTENZA+ water fi llter
Anima error 10.PNG The machine is waiting to start the water circuit priming process.
Anima error 11.PNG The milk carafe ducts should be cleaned.
Anima error 12.PNG The machine must be descaled.
Anima error 13.PNG The machine is heating up.
Anima error 14.PNG The machine is rinsing.
Anima error 15.PNG Brew group rebooting.
Machine Out of Service Description
Anima error 16.PNG If the machine error alarm signal is triggered, the error code is displayed in the bottom right corner of the display. XX (Following table)
Error Code Behavior Cause Action
1 Coffee grinder blocked Coffee outlet duct clogged Clean the coffee outlet duct thoroughly.
3 - 4 Brew group locked, cannot be taken out The brew group is incorrectly positioned. "Close the service door. Turn the machine off and back on again. Wait for the ‘Ready for brewing’ signal and then remove the brew group."
5 Water circuit error Air in the water circuit "Remove and restore the water tank a couple of times, making sure to position it correctly. Check that the water tank seat is clean."

Cleaning and Technical Servicing

A Empty the dregs drawer When indicated
B Empty the drip tray As necessary
C Clean the water tank Weekly
D Clean the coffee bean hopper As necessary
E Clean the casing As necessary
F Clean the brewing unit Every time the coffee bean hopper is filled or weekly
G Lubricate the brewing unit After 500 dispensing cycles or when the grease is no longer present on the brewing unit
H Clean the unit housing Weekly
I Descaling When indicated

Descaling Cycle Frequency

Hardness Water Hardness Without Water Filter With Water Filter
1 Soft water (up to 7°dH) Approx. every 6 months / 240 litres Approx. every 12 months / 480 litres
2 Medium water (7° - 14°dH) Approx. every 3 months / 120 litres Approx. every 6 months / 240 litres
3 Hard water (15° - 21°dH) Approx. every 6 weeks or 60 litres Approx. every 3 months / 120 litres
4 Very hard water (over 21°dH) Approx. every 4 weeks or 30 litres Approx. every 6 weeks or 60 litres

The default water hardness level is 3. Each litre of water corresponds to approximately 2,000 pulses

Babila

Error Code Brief Description Description
ErrorCode_01 Grinder blocked Grinder blocked: there is the absence of pulses from the grinder. In this case the C.A. It hangs in the instant in which the user asks the machine to dispense a drink made of coffee (only coffee beans).
ErrorCode_03 Brewing UNIT blocked work Brewing unit blocked work: Occurs when the brewing unit can not move from work to the home position.
ErrorCode_04 Brewing UNIT blocked home Brewing unit blocked home: Occurs when the brewing unit can not move from home to the work position
ErrorCode_05 Water circuit interrupted Water circuit interrupted: occurs when the flow meter is broken, disconnected or It does not occur passage of water. In these cases, since the C.A. can not correctly read the pulses of water, enters alarm condition “CHARGING CIRCUIT” in the moment in which the user asks to dispense a product: if the “charging circuit” fails C.A. blocked.
ErrorCode_06 DC valve short circuit DC Valve short circuit: occurs when one of the valves of the flute is shorted circuit. Such a problem may occur during dispensing of a product based on milk.
ErrorCode_10 Coffee temp. sensor short circuit Coffee temp. sensor short circuit: occurs when the temperature sensor coffee boiler is shorted. This error causes a blocking in C.A. to start-up.
ErrorCode_11 Coffee temp. sensor open circuit Coffee temp. sensor open circuit: occurs when the temperature sensor coffee boiler is not detected. The problem is due to the absence of the signal of the sensor and does not allow to determine the C.A. the actual temperature of the boiler coffee. At start up, the C.A. blocked.
ErrorCode_12 Steam temp. sensor open circuit Example
Example Example Steam temp. sensor open circuit: occurs when the temperature sensor steam boiler is not detected. The problem is due to the absence of the signal of the sensor and does not allow to determine the C.A. the actual temperature of the boiler steam. At start up, the C.A. blocked.
ErrorCode_13 Steam temp. sensor short circuit Steam temp. sensor short circuit: occurs when the temperature sensor boiler steam is shorted. This error causes a blocking in C.A. to start-up.
ErrorCode_14 Boiler coffee timeout Boiler coffee timeout: occurs when no power coming to the boiler coffee, this does not reach the predetermined temperature within a time equal to 120 seconds. At start-up the AC, is continually on the screen HOLD FIRST TEMPERATURE, with the message “Warming up ...”, and after the expiry of the time Out to fault
ErrorCode_15 Boiler steam timeout Boiler steam timeout: occurs when no power coming to the boiler steam, this does not reach the predetermined temperature within a time equal to 120 seconds.
ErrorCode_16 Brewing unit short circuit Coffee boiler overheating: occurs when the temperature of the coffee boiler exceeds 150 ° C.
ErrorCode_19 Zero crossing error Steam boiler overheating: occurs when the temperature of the steam boiler exceeds 170 ° C.
ErrorCode_20 Boiler coffee overheating Brewing unit short circuit: occurs when the supply of the complete group has in short circuit.
ErrorCode_21 Boiler steam overheating Zero crossing error: occurs when the C.A. It does not detect the signal zero crossing.

Descaling Cycle Frequency

Hardness Water Hardness Without Water Filter Not Reactivating the Filter
1 Soft water (up to 7°dH) Approx. every 6 months / 240 litres 210 litres
2 Medium water (7° - 14°dH) Approx. every 3 months / 120 litres 105 litres
3 Hard water (15° - 21°dH) Approx. every 6 weeks or 60 litres 52.5 litres
4 Very hard water (over 21°dH) Approx. every 4 weeks or 30 litres 26.25 litres

The default water hardness level is 4. Each litre of water corresponds to approximately 2,000 pulses.