Accademia Error Codes
Error Code | Brief Description | Description |
---|---|---|
01 | blocked coffee grinder | the coffee grinder is blocked (jammed grinder blades or sensor is not reading properly) |
03 | brewing unit blocked in ‘work’ | descending time-out exceeded |
04 | brewing unit blocked in ‘home’ | ascending time-out exceeded |
05 | blocked water circuit | water does not flow in the flow meter |
06 | frother unit solenoid valve | short circuit in a solenoid valve of the frother unit |
10 | coffee boiler short circuit | coffee boiler temperature sensor short circuit |
11 | coffee boiler in open circuit | coffee boiler temperature sensor in open circuit |
12 | steam boiler short circuit | steam boiler temperature sensor short circuit |
13 | steam boiler in open circuit | steam boiler temperature sensor in open circuit |
14 | various temperature errors (in the coffee boiler) | coffee boiler temperatures out of control |
15 | various temperature errors (in the steam boiler) | steam boiler temperatures out of control |
16 | coffee unit short circuit | brewing unit microswitch short circuit |
18 | clock error | memory fault or impossible to set |
19 | no zero crossing | no zero crossing on board, could also be caused by the power board |
Accademia Descaling Cycle Frequency
Hardness | Water Hardness | Without Water Filter | With Water Filter |
---|---|---|---|
1 | Soft water (up to 7°dH) | "Approx. every 6 months / 240 litres" | Approx. every 12 months / 480 litres |
2 | Medium water (7° - 14°dH) | Approx. every 3 months / 120 litres | "Approx. every 6 months / 240 litres" |
3 | Medium water (7° - 14°dH) | "Approx. every 6 weeks or 60 litres" | "Approx. every 3 months / 120 litres" |
4 | "Very hard water (over 21°dH)" | "Approx. every 4 weeks or 30 litres" | "Approx. every 6 weeks or 60 litres" |
The default water hardness level is 3. Each litre of water corresponds to approximately 2,000 pulses
Anima Error Key
Machine Out of Service | Description |
---|---|
If the machine error alarm signal is triggered, the error code is displayed in the bottom right corner of the display. XX (Following table) |
Error Code | Behavior | Cause | Action |
---|---|---|---|
1 | Coffee grinder blocked | Coffee outlet duct clogged | Clean the coffee outlet duct thoroughly. |
3 - 4 | Brew group locked, cannot be taken out | The brew group is incorrectly positioned. | "Close the service door. Turn the machine off and back on again. Wait for the ‘Ready for brewing’ signal and then remove the brew group." |
5 | Water circuit error | Air in the water circuit | "Remove and restore the water tank a couple of times, making sure to position it correctly. Check that the water tank seat is clean." |