| 01 || blocked coffee grinder || the coffee grinder is blocked (jammed grinder blades or sensor is not reading properly) || [[Gaggia_Accademia/troubleshooting#No_Beans.2C_Grinder_Blocked.2C_Or_E01| Follow these instructions.]] | | 01 || blocked coffee grinder || the coffee grinder is blocked (jammed grinder blades or sensor is not reading properly) || [[Gaggia_Accademia/troubleshooting#No_Beans.2C_Grinder_Blocked.2C_Or_E01| Follow these instructions.]] | ||
|- | |- | ||
− | | 03 || brewing unit blocked in ‘work’ || descending time-out exceeded || | + | | 03 || brewing unit blocked in ‘work’ || descending time-out exceeded || [https://wiki.wholelattelove.com/Gaggia_Accademia/troubleshooting#Brew_Unit_Max_Pressure.2C_Stuck.2C_or_E03_or_E04_Error_Codes Follow these instructions.] |
|- | |- | ||
− | | 04 || brewing unit blocked in ‘home’ || ascending time-out exceeded || [ | + | | 04 || brewing unit blocked in ‘home’ || ascending time-out exceeded || [http://Follow%20these%20instructions. Follow these instructions.] |
|- | |- | ||
− | | 05 || blocked water circuit || water does not flow in the flow meter || | + | | 05 || blocked water circuit || water does not flow in the flow meter || [https://wiki.wholelattelove.com/Gaggia_Accademia/troubleshooting#Flow_Issues Follow these instructions.] |
|- | |- | ||
| 06 || frother unit solenoid valve || short circuit in a solenoid valve of the frother unit || The unit will need professional repairs. | | 06 || frother unit solenoid valve || short circuit in a solenoid valve of the frother unit || The unit will need professional repairs. | ||
Line 30: | Line 30: | ||
| 18 || clock error || memory fault or impossible to set || The unit will need professional repairs. | | 18 || clock error || memory fault or impossible to set || The unit will need professional repairs. | ||
|- | |- | ||
− | | 19 || no zero crossing || no zero crossing on board, could also be caused by the power board || | + | | 19 || no zero crossing || no zero crossing on board, could also be caused by the power board || [https://wiki.wholelattelove.com/Troubleshooting-Gaggia-Super-E05-Accademia Follow these instructions.] If the error continues, the control board may be malfunctioning and the unit will need professional repairs. |
|} | |} | ||
Revision as of 11:07, 7 October 2020
Contents
Accademia Error Codes
Error Code | Brief Description | Description | Solution |
---|---|---|---|
01 | blocked coffee grinder | the coffee grinder is blocked (jammed grinder blades or sensor is not reading properly) | Follow these instructions. |
03 | brewing unit blocked in ‘work’ | descending time-out exceeded | Follow these instructions. |
04 | brewing unit blocked in ‘home’ | ascending time-out exceeded | Follow these instructions. |
05 | blocked water circuit | water does not flow in the flow meter | Follow these instructions. |
06 | frother unit solenoid valve | short circuit in a solenoid valve of the frother unit | The unit will need professional repairs. |
10 | coffee boiler short circuit | coffee boiler temperature sensor short circuit | The unit will need professional repairs. |
11 | coffee boiler in open circuit | coffee boiler temperature sensor in open circuit | The unit will need professional repairs. |
12 | steam boiler short circuit | steam boiler temperature sensor short circuit | The unit will need professional repairs. |
13 | steam boiler in open circuit | steam boiler temperature sensor in open circuit | The unit will need professional repairs. |
14 | various temperature errors (in the coffee boiler) | coffee boiler temperatures out of control | The unit will need professional repairs. |
15 | various temperature errors (in the steam boiler) | steam boiler temperatures out of control | The unit will need professional repairs. |
16 | coffee unit short circuit | brewing unit microswitch short circuit | The unit will need professional repairs. |
18 | clock error | memory fault or impossible to set | The unit will need professional repairs. |
19 | no zero crossing | no zero crossing on board, could also be caused by the power board | Follow these instructions. If the error continues, the control board may be malfunctioning and the unit will need professional repairs. |
Accademia Descaling Cycle Frequency
Hardness | Water Hardness | Without Water Filter | With Water Filter |
---|---|---|---|
1 | Soft water (up to 7°dH) | "Approx. every 6 months / 240 litres" | Approx. every 12 months / 480 litres |
2 | Medium water (7° - 14°dH) | Approx. every 3 months / 120 litres | "Approx. every 6 months / 240 litres" |
3 | Medium water (7° - 14°dH) | "Approx. every 6 weeks or 60 litres" | "Approx. every 3 months / 120 litres" |
4 | "Very hard water (over 21°dH)" | "Approx. every 4 weeks or 30 litres" | "Approx. every 6 weeks or 60 litres" |
The default water hardness level is 3. Each litre of water corresponds to approximately 2,000 pulses
Anima Error Key
Machine Out of Service | Description |
---|---|
If the machine error alarm signal is triggered, the error code is displayed in the bottom right corner of the display. XX (Following table) |
Error Code | Behavior | Cause | Action |
---|---|---|---|
1 | Coffee grinder blocked | Coffee outlet duct clogged | Clean the coffee outlet duct thoroughly. |
3 - 4 | Brew group locked, cannot be taken out | The brew group is incorrectly positioned. | "Close the service door. Turn the machine off and back on again. Wait for the ‘Ready for brewing’ signal and then remove the brew group." |
5 | Water circuit error | Air in the water circuit | "Remove and restore the water tank a couple of times, making sure to position it correctly. Check that the water tank seat is clean." |
Cleaning and Technical Servicing
A | Empty the dregs drawer | When indicated |
B | Empty the drip tray | As necessary |
C | Clean the water tank | Weekly |
D | Clean the coffee bean hopper | As necessary |
E | Clean the casing | As necessary |
F | Clean the brewing unit | Every time the coffee bean hopper is filled or weekly |
G | Lubricate the brewing unit | After 500 dispensing cycles or when the grease is no longer present on the brewing unit |
H | Clean the unit housing | Weekly |
I | Descaling | When indicated |
Descaling Cycle Frequency
Hardness | Water Hardness | Without Water Filter | With Water Filter |
---|---|---|---|
1 | Soft water (up to 7°dH) | Approx. every 6 months / 240 litres | Approx. every 12 months / 480 litres |
2 | Medium water (7° - 14°dH) | Approx. every 3 months / 120 litres | Approx. every 6 months / 240 litres |
3 | Hard water (15° - 21°dH) | Approx. every 6 weeks or 60 litres | Approx. every 3 months / 120 litres |
4 | Very hard water (over 21°dH) | Approx. every 4 weeks or 30 litres | Approx. every 6 weeks or 60 litres |
The default water hardness level is 3. Each litre of water corresponds to approximately 2,000 pulses
Babila
Error Code | Brief Description | Description |
---|---|---|
ErrorCode_01 | Grinder blocked | Grinder blocked: there is the absence of pulses from the grinder. In this case the C.A. It hangs in the instant in which the user asks the machine to dispense a drink made of coffee (only coffee beans). |
ErrorCode_03 | Brewing UNIT blocked work | Brewing unit blocked work: Occurs when the brewing unit can not move from work to the home position. |
ErrorCode_04 | Brewing UNIT blocked home | Brewing unit blocked home: Occurs when the brewing unit can not move from home to the work position |
ErrorCode_05 | Water circuit interrupted | Water circuit interrupted: occurs when the flow meter is broken, disconnected or It does not occur passage of water. In these cases, since the C.A. can not correctly read the pulses of water, enters alarm condition “CHARGING CIRCUIT” in the moment in which the user asks to dispense a product: if the “charging circuit” fails C.A. blocked. |
ErrorCode_06 | DC valve short circuit | DC Valve short circuit: occurs when one of the valves of the flute is shorted circuit. Such a problem may occur during dispensing of a product based on milk. |
ErrorCode_10 | Coffee temp. sensor short circuit | Coffee temp. sensor short circuit: occurs when the temperature sensor coffee boiler is shorted. This error causes a blocking in C.A. to start-up. |
ErrorCode_11 | Coffee temp. sensor open circuit | Coffee temp. sensor open circuit: occurs when the temperature sensor coffee boiler is not detected. The problem is due to the absence of the signal of the sensor and does not allow to determine the C.A. the actual temperature of the boiler coffee. At start up, the C.A. blocked. |
ErrorCode_12 | Steam temp. sensor open circuit | Example |
Example | Example | Steam temp. sensor open circuit: occurs when the temperature sensor steam boiler is not detected. The problem is due to the absence of the signal of the sensor and does not allow to determine the C.A. the actual temperature of the boiler steam. At start up, the C.A. blocked. |
ErrorCode_13 | Steam temp. sensor short circuit | Steam temp. sensor short circuit: occurs when the temperature sensor boiler steam is shorted. This error causes a blocking in C.A. to start-up. |
ErrorCode_14 | Boiler coffee timeout | Boiler coffee timeout: occurs when no power coming to the boiler coffee, this does not reach the predetermined temperature within a time equal to 120 seconds. At start-up the AC, is continually on the screen HOLD FIRST TEMPERATURE, with the message “Warming up ...”, and after the expiry of the time Out to fault |
ErrorCode_15 | Boiler steam timeout | Boiler steam timeout: occurs when no power coming to the boiler steam, this does not reach the predetermined temperature within a time equal to 120 seconds. |
ErrorCode_16 | Brewing unit short circuit | Coffee boiler overheating: occurs when the temperature of the coffee boiler exceeds 150 ° C. |
ErrorCode_19 | Zero crossing error | Steam boiler overheating: occurs when the temperature of the steam boiler exceeds 170 ° C. |
ErrorCode_20 | Boiler coffee overheating | Brewing unit short circuit: occurs when the supply of the complete group has in short circuit. |
ErrorCode_21 | Boiler steam overheating | Zero crossing error: occurs when the C.A. It does not detect the signal zero crossing. |
Descaling Cycle Frequency
Hardness | Water Hardness | Without Water Filter | Not Reactivating the Filter |
---|---|---|---|
1 | Soft water (up to 7°dH) | Approx. every 6 months / 240 litres | 210 litres |
2 | Medium water (7° - 14°dH) | Approx. every 3 months / 120 litres | 105 litres |
3 | Hard water (15° - 21°dH) | Approx. every 6 weeks or 60 litres | 52.5 litres |
4 | Very hard water (over 21°dH) | Approx. every 4 weeks or 30 litres | 26.25 litres |
The default water hardness level is 4. Each litre of water corresponds to approximately 2,000 pulses.
Besana
Brera
Cleaning and Technical Servicing
A | Empty the dregs drawer | When indicated |
B | Empty the drip tray | As necessary |
C | Clean the water tank | Weekly |
D | Clean the coffee bean hopper | As necessary |
E | Clean the casing | As necessary |
F | Clean the brewing unit | Every time the coffee bean hopper is filled or weekly |
G | Lubricate the brewing unit | After 500 dispensing cycles or when the grease is no longer present on the brewing unit |
H | Clean the unit housing | Weekly |
I | Descaling | When indicated |
Descaling Cycle Frequency
Hardness | Water Hardness | Without Water Filter | With Water Filter |
---|---|---|---|
1 | Soft water (up to 7°dH) | Approx. every 3 months / 120 litres | Approx. every 6 months / 240 litres |
2 | Medium water (7° - 14°dH) | Approx. every 2 months / 90 litres | Approx. every 4 months / 180 litres |
3 | Hard water (15° - 21°dH) | Approx. every 6 weeks or 60 litres | Approx. every 3 months / 120 litres |
4 | Very hard water (over 21°dH) | Approx. every 4 weeks or 30 litres | Approx. every 6 weeks or 60 litres |
Cadorna
Error Code | Description |
---|---|
01 | The coffee grinder is blocked |
02 | The grinder is disconnected (Only coffee grinder without electronic sensor) |
03 | The brewing unit is blocked in work position |
04 | The brewing unit is blocked in home position |
05 | The hydraulic circuit is clogged |
10 | The temperature sensor is in short circuit |
11 | The temperature sensor is opened |
14 | The temperature was up to 170° |
19 | The net is not stable |
20 | Boiler coffee overheating |
Descaling Cycle Frequency
Hardness | Water Hardness | Without Water Filter | With Water Filter |
---|---|---|---|
1 | Soft water (up to 7°dH) | Approx. every 6 months / 240 litres | Approx. every 12 months / 480 litres |
2 | Medium water (7° - 14°dH) | Approx. every 3 months / 120 litres | Approx. every 6 months / 240 litres |
3 | Hard water (15° - 21°dH) | Approx. every 6 weeks or 60 litres | Approx. every 3 months / 120 litres |
4 | Very hard water (over 21°dH) | Approx. every 4 weeks or 30 litres | Approx. every 6 weeks or 60 litres |
The default water hardness level is 4. Each litre of water corresponds to approximately 1936 pulses.
Velasca
Error Code | Description |
---|---|
01 | Grinder fail |
02 | The grinder is disconnected (Only coffee grinder without electronic sensor) |
03 | Bu movement toward WORK fail |
04 | Bu movement toward HOME fail |
05 | Water circuit fail |
10 | NTC short circuit fail |
11 | NTC open circuit fail |
14 | Heater over-temperature fail |
15 | Heater time-out fail |
19 | Zero-Crossing fail |
Descaling Cycle Frequency
Hardness | Water Hardness | Without Water Filter | Not Reactivating the Filter |
---|---|---|---|
1 | Soft water (up to 7°dH) | Approx. every 6 months / 240 litres | 210 litres |
2 | Medium water (7° - 14°dH) | Approx. every 3 months / 120 litres | 105 litres |
3 | Hard water (15° - 21°dH) | Approx. every 6 weeks or 60 litres | 52.5 litres |
4 | Very hard water (over 21°dH) | Approx. every 4 weeks or 30 litres | 26.25 litres |
The default water hardness level is 4. Each litre of water corresponds to approximately 2,000 pulses.