Error Code Brief Description Description
01 blocked coffee grinder the coffee grinder is blocked (jammed grinder blades or sensor is not reading properly)
03 brewing unit blocked in ‘work’ descending time-out exceeded
04 brewing unit blocked in ‘home’ ascending time-out exceeded
05 blocked water circuit water does not flow in the flow meter
06 frother unit solenoid valve short circuit in a solenoid valve of the frother unit
10 coffee boiler short circuit coffee boiler temperature sensor short circuit
11 coffee boiler in open circuit coffee boiler temperature sensor in open circuit
12 steam boiler short circuit steam boiler temperature sensor short circuit
13 steam boiler in open circuit steam boiler temperature sensor in open circuit
14 various temperature errors (in the coffee boiler) coffee boiler temperatures out of control
15 various temperature errors (in the steam boiler) steam boiler temperatures out of control
16 coffee unit short circuit brewing unit microswitch short circuit
18 clock error memory fault or impossible to set
19 no zero crossing no zero crossing on board, could also be caused by the power board